621-000-000 | 1980-11-01 | 57 | 80.33 KB | Numerical Index - Division 621 - Pole Lines |
621-000-000PT X1 | 1980-04-01 | G | 138.50 KB | Pacific Tel. - Numerical Index - Division 621 - Pole Lines |
621-200-011 | 1968-10-01 | 2 | 769.47 KB | Poles - Locating, Preparing, and Soil Bracing |
621-200-203 | 1976-06-01 | 2 | 1.41 MB | Loading and Binding Poles on Pole Trailers |
621-200-205 | 1968-09-01 | 2 | 219.79 KB | Poles - Markings and Insignia |
621-205-010 | 1976-09-01 | 8 | 368.34 KB | Placing or Removing Poles Near Electric Power Lines |
621-205-200 | 1968-11-01 | 2 | 365.62 KB | Erecting Poles and Stubs |
621-205-211 | 1968-09-01 | 3 | 218.84 KB | Placing Pole Braces and H Fixtures |
621-205-215 | 1968-12-01 | 2 | 219.91 KB | Erecting Poles - Installing Lightning Protection |
621-210-011 | 1975-08-01 | 4 | 1.30 MB | Stepping Poles - General |
621-210-011PT A | 1974-11-01 | A | 34.73 KB | Stepping Poles (For California Only) |
621-210-012 | 1976-06-01 | 1 | 981.86 KB | Stepping Poles - General |
621-210-012 | 1985-12-01 | 3 | 218.91 KB | Stepping Poles - General |
621-210-900PT | 1975-12-01 | B | 156.66 KB | Stepping Poles - B-Type Cross-Connecting Terminals and 29-Type Cabinets |
621-210-900PT A | 1976-02-01 | A | 32.01 KB | Stepping Poles - B-Type Cross-Connecting Terminals and 29-Type Cabinets |
621-215-015 | 1975-09-01 | 5 | 433.26 KB | Pole Lines - Inspection of Poles |
621-215-681 | 1966-12-01 | 1 | 472.10 KB | Pole Lines - Minimum Circumfrences At Critical Section - 3600 Pound Fiber Strength - All Storm Loading Areas - All Pole Lengths |
621-215-682 | 1966-12-01 | 1 | 535.68 KB | Pole Lines - Minimum Circumfrences At Critical Section - 6000 Pound Fiber Strength - All Storm Loading Areas - All Pole Lengths |
621-215-683 | 1966-12-01 | 1 | 481.69 KB | Pole Lines - Minimum Circumfrences At Critical Section - 6600 Pound Fiber Strength - All Storm Loading Areas - All Pole Lengths |
621-215-684 | 1966-12-01 | 1 | 518.95 KB | Pole Lines - Minimum Circumfrences At Critical Section - 7400 Pound Fiber Strength - All Storm Loading Areas - All Pole Lengths |
621-215-685 | 1966-12-01 | 1 | 539.52 KB | Pole Lines - Minimum Circumfrences At Critical Section - 8000 Pound Fiber Strength - All Storm Loading Areas - All Pole Lengths |
621-215-686 | 1966-12-01 | 1 | 541.26 KB | Pole Lines - Minimum Circumfrences At Critical Section - 8400 Pound Fiber Strength - All Storm Loading Areas - All Pole Lengths |
621-220-200 | 1974-01-01 | 2 | 295.63 KB | Pole Removal |
621-295-320 | 1969-08-01 | 2 | 277.39 KB | Pole Replacing |
621-300-940PT | 1963-04-01 | B | 182.74 KB | Pole Attachments - Placing Guard Arms |
621-400-011 | 1973-03-01 | 3 | 167.71 KB | Guying - Definitions |
621-400-013 | 1979-07-01 | 5 | 285.80 KB | Guying - Use of Guy Rule - Sizes of Guys |
621-400-015 | 1970-03-01 | 3 | 89.19 KB | Guying - Insulated Wires |
621-405-201 | 1977-06-01 | 4 | 184.42 KB | Guying - Methods of Insulating |
621-410-200 | 1976-11-01 | 5 | 580.97 KB | Guying - Methods of Installation |
621-410-206 | 1977-06-01 | 3 | 213.60 KB | Guying - Aerial Cable Lines |
621-410-220 | 1977-08-01 | 3 | 114.06 KB | Guying - Sidewalk Anchor Guys |
621-415-011 | 1961-03-01 | 1 | 73.29 KB | Patent Guy Anchors - General |
621-415-200 | 1974-03-01 | 4 | 175.72 KB | Patent Guy Anchors - Expanding Anchors |
621-415-204 | 1984-05-01 | 2 | 1.99 MB | C Guy Anchor (AT-8891) - Power Installation |
621-415-217 | 1973-09-01 | 5 | 68.41 KB | Guying - Extending Length of or Adding Additional Eye to Existing Guy Rods |
621-420-241 | 1969-07-01 | 2 | 142.44 KB | Removal of Guys and Anchors |